Description
50 Amp Electronic Marine Converter with Charger Wizard PD2150
Replaced by the PD2160V
The PD2150 is a 50-amp Electronic Marine Converter/Charger capable of charging up to three separate banks of batteries at the same time. It incorporates a microprocessor that constantly monitors battery voltage, then automatically selects one of four operating modes to ensure safe, rapid recharging cycles. The Storage Mode and the Equalize Mode of operation ensures minimum battery gassing and water loss while preventing battery stratification and sulfation. All Inteli-Power chargers are designed to meet the stringent requirements of the Marine environment and are UL listed for safety. A digital meter displays current, voltage, operation mode, blown fuse indication, and battery type.
50 Amp Electronic Marine Converter with Charger Wizard for Gell Cell Batteries Special Order The PD2050 is a 50-amp electronic battery charger capable of charging up to three separate banks of batteries at the same time. It incorporates a microprocessor that constantly monitors battery voltage, then automatically selects one of three different charging voltages and one of four operating modes to ensure safe, rapid recharging cycles. The Storage Mode and the Equalize Mode of operation ensures minimum battery gassing and water loss while preventing battery stratification and sulfation. All Inteli-Power chargers are designed to meet the stringent requirements of the Marine environment and are UL listed for safety. REVERSE BATTERY PROTECTION PREVENTS CHARGER DAMAGE IF BATTERY LEADS ARE ACCIDENTALLY REVERSED LOWER VOLTAGES TO SAFELY RECHARGE GEL-CELL BATTERIES CHARGES UP TO THREE BATTERY BANKS BUILT-IN HIGH VOLTAGE PROTECTION BUILT-IN AMPMETER IS STANDARD QUIET SENSOR FAN ELECTRONIC SHORT CIRCUIT PROTECTION OVER TEMPERATURE SAFETY SHUTDOWN The Progressive Dynamics INTELI-POWER MARINE series of marine battery chargers incorporate a built-in microprocessor that constantly monitors battery voltage. Depending on battery voltage and use, the microprocessor then selects one of three different charging voltages and one of four operating modes (Boost, Normal, Storage or Equalize) to ensure a safe rapid recharge. If the microprocessor senses the battery has been heavily discharged, it automatically selects the Boost Mode, increasing the charging voltage to 14.4 volts to bring the battery up to 90% of full charge as rapidly as possible. The system then automatically switches to the Normal Mode, 13.6 volts, to safely complete the charge. If the battery is fully charged and the 12 volt electrical systems are turned off for a period of 30 hours, the system selects the Storage Mode, 13.2 volts. This lower voltage reduces battery gassing and water loss. To prevent battery sulfation and stratification during the Storage Mode of operation, the system selects the Equalize Mode every 21 hours for a period of 15 minutes. The Equalize Mode increases the voltage to 14.4 volts for a 15-minute period to eliminate battery sulfation and stratification problems. Input Voltage: 120 VAC Frequency: 60 Hz Watts: 900 Watts Output Voltage: 13 VDC Current: 50 Amps Charge Rate Up To: 50 Amps
Features
Four-Stage Charging System
patented Microprocessor constantly monitors battery voltage and automatically selects one of the four charging modes; BOOST, NORMAL, STORAGE or EQUALIZE.
3 Diode Isolated Outputs
allows the converter/charger to charge three separate banks of batteries. Each output is capable of handling the full rated current of the charger.
Patented Reverse Battery Protection
prevents converter/charger from being damaged if the batteries are accidentally connected to the charger in reverse.
Over Voltage Protection
prevents high voltage spikes from damaging the converter/charger.
Electronic Current Limiting
limits the output current to the maximum rating of the charger to prevent overheating and damage caused by shorts or excessive loads.
Variable Speed Intelligent Cooling Fan
only runs as fast as required to maintain a more constant operating temperature inside the converter/charger. This feature reduces thermal stress caused by fans that cycle on and off.
Programmable in the Field
to provide optimum charging profiles for lead-acid, gel-cell, or AGM batteries.
Regulated Output Voltage
prevents AC Line voltage variations from being transmitted to the batteries and 12 volt circuits.
Automatic Over-Temperature Shutdown
prevents converter/charger damage in the event the fan is unable to cool the charger due to inadequate compartment ventilation.
Series or Parallel Connection
Inteli-Power Converter/Chargers can be connected in series to provide a combination 12/24 Volt system, or in parallel to provide more current.